Sometimes we have had some trouble in removing the i-Gel® while carrying out the procedure with nasopharyngeal cannula, and the ETT has been about to leave its proper position inside the trachea. This could be due to several causes: Improper ETT lubrication, an ETT of the maximum size allowed for the i-Gel®'s lumen, thereby causing friction, or maybe because of the cannula's material, since as it is made of plastic, it may not be rigid enough to properly hold the ETT. Perhaps, it could be a combination of all these situations. However, we haven't had any trouble in more than one hundred endotracheal intubations through the i-Gel® using Magill forceps for its removal. Of course, care should be taken when inserting the forceps to hold the ETT, since its cuff may be damaged. We, therefore, consider that Magill forceps are successful as an alternative in helping to remove i-Gel® after endotracheal intubation through the device, and we hope you can try it in your daily practice.
We have read with great interest the recently published paper “Nasopharyngeal airway as an aid to remove i-Gel® after endotracheal intubation through the device”[1] and we agree on the need for some specific device to hold the endotracheal tube (ETT) while i-Gel® is removed after endotracheal intubation through the device. During recent years, it seems that fibreoptic guided intubation through the i-Gel® is becoming more frequent since it's an easy and safe technique for the patient.[2] In our institution, we have been using i-Gel® since 2009. For us, this is a routinely and highly effective intubation technique, especially for expected difficult airway patients. We have tried several devices to remove i-Gel® holding the ETT in its proper position, such as nasopharyngeal cannula, another ETT on top of the ETT and even the Fastrach ® mask exchanger. However, after several years we have come to the conclusion that the most effective and safe method is using Magill forceps as an ETT holder [Figure 1]. Magill forceps were first described by Magill in 1920[3], and they are used as an aid for nasotracheal intubation as well as to remove foreign bodies.[4,5] The ease and safety they bring may be due to its easy handling, and since they are metallic, they are rigid enough to firmly hold the ETT in place.
Address for correspondence: Dr. Julian Arevalo Ludeña, Av. Reyes Catolicos 2, 28040 Madrid, Spain. E-mail: jarevalo@fjd.es
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
Please complete the fields below to send your friend a link to this product. Your friend will receive an email from you with a link to our site.
Articles from Journal of Anaesthesiology, Clinical Pharmacology are provided here courtesy of Wolters Kluwer -- Medknow Publications
The item you are trying to purchase is currently out of stock.Please enter your name, email, and phone number below. We will contact you as soon as this product is available.